AT
Systems Offer Advanced Technology
and High Performance At A Low
Cost!
The Cattron-Theimeg AT Series offer
the safety and dependability required for operating machinery in
harsh, industrial environments. AT Series Systems can be installed
on overhead cranes; furnace doors; conveyors, shiploading equipment,
mining machinery, agricultural equipment; and much more.
All Cattron-Theimeg AT Series Systems
are custom engineered to meet individual application needs, and
can be engineered for up to 32 outputs and/or stepless. The AT-S
is a pre-engineered version offering faster delivery and all the
advantages of the standard AT without the need for an FCC or DOC
license. Check with your Cattron-Theimeg representative for complete
details.
Receiver/Decoder
All receiver/decoder units (shown above)
used with the AT are high quality, industrial units which are housed
in compact NEMA 12 (IP 65) enclosures. The AT utilizes high-performance
microprocessors with a minimum number of components. A single board
receiver/decoder responds to the direct control of a rugged, hand-held
controller/transmitter. The entire electronics portion of the receiver/decoder
is protected with an EMI/RFI shielded sub-chassis (gold box). This
compartmentalized chassis contains the power supply, the RF receiver,
and the microprocessor-based decoder.
AT Series systems are available with
options such as Close Start™, Range Limiting™, and Multi-Frequency
Using Synthesis. Multiple microprocessors prevent undesired signals
from entering the decoder, thereby improving operation and reliability.
AT decoders incorporate extensive self-diagnostics
which perform on a continuous basis to insure reliable and safe
operation. A two character status display shows both normal running
status and any fault conditions. Outputs are connected to the relay
interface via a single ribbon cable. Long-life electromechanical
relays are organized for easy function recognition. All relays plug
into sockets with mechanical hold-down screws and snubber circuits
are provided for inductive loads. LED's located beside each relay
show, at a glance, when it is energized.
Cattron-Theimeg application engineers
ensure that all AT receiver/decoders are programmable. This allows
for complex sequential logic, function timing, interlock, etc.,
to be built-in, often eliminating the need for a second interface,
such as a PLC with timers and latching relays. Because the AT is
programmable, they can be adapted to a wide variety of equipment.
AT systems will also work with several different Cattron-Theimeg
controller/transmitter styles.
Key Features
- Low cost per output
- 1-32 relay outputs + ON/OFF (mainline)
- Extensive self-diagnostics
- Single point status display shows
normal and fault condition
- "Dry" relay contact outputs
which allow mixed control voltages
- Automatic safety override (ASO)
output verification
- Custom factory engineering for each
application (AT only)
- Simplified installation with complete
custom wiring diagrams
- Multiple "watch dog" timers
provide redundancy to insure that no motion is carried out without
Command (total of five – two hardware, three software for
CPU, Mainline, & Motor Functions)
- Compact enclosure
- EMI/RFI shielded/compartmentalized
sub-chassis
- No motherboard or card cage
- Plug-in micro-controller with e-prom
allows quick "personality" changes (reduces need for
spare controllers)
- Multiple power supply options
- FCC/DOC/EC non-licensed and licensed
systems available
- Long "ride thru" time
during power interruptions to the receiver/decoder
- Diagnostic software for PC available
- Stepless output available for smoother
operation and control
- Can be configured with several different
controller/transmitter styles

Check Controller
page for available styles
Technical Specifications:
Interface Type: Mechanical
relays normally open contacts of 8 A @ 250 VAC or 5 A @ 30 VDC.
(Outputs fused at 5 Amps; normally closed contacts optional)
Output Termination: Two screw
terminals per relay contact allowing for mixed control voltages
and transformer (two 14 AWG per terminal)
Number of outputs: 1-32 independent
and /or simultaneous, plus mainline on/off (operate)
Enclosure: NEMA 12 (IP65) standard
- dust, water and oil tight; NEMA 4 and 4X (IP66) optional
Dimensions: AT-16: 12"H
x 10"W x 4.5"D (305mm x 254mm x 115mm);
AT-32: 14"H x 12"W x 6"D
(375mm x 330mm x 165mm)
Control Voltage Range: 30 VDC
or 12-250 VAC fused @ 5Amps (higher voltages with derated current);
Stepless: 0-80V Bipolar maximum
Power Requirements: 32/48/110/220VAC
50-60Hz or 12 VDC +/- 20% @ less than 1 Amp; optional 12 to 48 VDC
power regulators available
Receiver Frequency (Crystal &
Synthesized): 72 - 76 MHz, 403 - 424 MHz or 447 - 471 MHz (Radio);
880 nanometers (Infrared)
Sensitivity: 0.5 uV (20 dB quieting)
typical
Frequency Stability: +/- 0.0005%
of reference frequency
Environmental: approx. -4ºF
to +140ºF (-20ºC to +60ºC), RH 0 to 95%, non-condensing (special
units available)
Microcomputer Speed: 12MHz
Memory Size: E-Prom 32K bytes
(programmed by Cattron-Theimeg™) EE-Prom 512 bytes (field
programmable)
Optional diagnostic Port: RS232C
(DB25 Connector) or RS422 (MTA Connector)
RF Range: 300 ft. nominal (92m)
(no license required); 800+ ft. (246+m) dependant on local conditions
*Specifications
subject to change without notice
|